HPR Series gas analysers
The HPR series of mass spectrometer-based gas analysers from Hiden Analytical has been expanded further to include analysis of static off-line gas samples in addition to the more routine conditions of dynamic flow. New additions include the HPR-70 bench-top system for gas composition measurement of small individual discreet samples with the gas preparation stage including selectable cascade volumes for pressure optimisation over a wide spread of sample volumes and sample pressures. Samples will normally be acquired and contained off-line as the container has an isolation valve or break-seal for direct connection to the mass spectrometer. The HPR-90 system uses similar mass spectrometer stages together with a customised inlet system specifically configured for analysis of gases trapped within enclosed volumes. It is totally enclosed within a UHV-compatible evacuated vacuum vessel and is equipped with appropriate cracking or drilling facilities to enable release of the gas sample for immediate analysis. Package volumes from 10 litres down to sub-millilitres are accommodated. The systems offer a choice of manual or automated operation and include multiple calibration routines for data quantification, enabling measurement of low-level gas components to the sub-ppm level.
More information:
Free Webinar

View this Free Webinar
- Most Read
- Highly Rated
- Mass spectrometry investigations of nanoparticles by tandem charge detection mass spectrometry (5 from 9 votes)
- New bulk analysis spectroscopy technique (5 from 6 votes)
- Raman for diabetes monitoring (5 from 6 votes)
- Fluorescence eye test reveals neurological diseases in livestock (5 from 4 votes)
- The First Spectroscopic Measurement of an Anti-Atom (5 from 4 votes)
Latest Comments
-
Gujarathi Dipak B. said More...Sir,
This is an excellent appl... 8 months ago -
Rakesh Kanda said More...Dr Alfonso,
Matrix suppression is ... 1 year ago -
Dr Robson JCF Afonso said More...Dear Authors,
As you sad atmospheric... 1 year ago -
Dr Robson JCF Afonso said More...I am glad to hearing someone question... 2 years ago
-
Peter Jenks said More...That is a reason I\'d overlooked - po... 2 years ago
Contents Alerts
Popular Techniques
- Atomic absorption
- Atomic emission
- Chemometrics
- ICP-MS
- Imaging
- Infrared
- Ion mobility
- Laser spectroscopy
- Luminescencefluorescence
- Mass spectrometry
- Microscopy
- Mobile
- MRI
- Near infrared
- NMR ESR EPR
- Polarimetry
- Process
- Raman
- Related equipment
- RMs and standards
- Sample prep
- Separation science
- Software
- Surface analysis
- Terahertz
- UVvis
- X-ray spectrometry